TM 5-4310-452-14
Table 2-1. Operator Preventive Maintenance Checks and Services (PMCS).
B-Before D-During A-After W-Weekly
Interval ITEM TO BE INSPECTED Equipment is
Item PROCEDURE: Check for and have repaired Not Ready
No. B D A W filled or adjusted as needed Available If:
NOTE
Perform these checks in the order listed,
within the designated interval, as you walk
around the compressor unit.
Perform Before (B) and Weekly (W) PMCS if:
a. You are the assigned operator and have
not operated the compressor unit since
the last weekly check.
b. You are operating the compressor for the
first time.
If the compressor unit must be kept in
continuous operation, check and service
only those items that will not disturb
operation. Complete the remaining checks
and services when the unit can be shut
down,
1 VEHICLE EXTERIOR
a. Check for fluid leakage or appearance of fluid Any Class III leaks are found.
leakage,
b. Visually check for damaged piping or hoses, and Piping or hoses are leaking or
loose, missing, or damaged parts. broken. Parts are missing or
damaged.
c. Operate lights.
d. Leveling jacks operate properly. If leveling jacks
are missing or damaged, notify your supervisor.
2 TIRES
Check for excessive wear, cuts, cracks, abrasions,
and low or flat tires. Ensure that tires are inflated to
60 psi (448 kPa).
3 FUEL/WATER SEPARATOR
Check for water in sightbowl. If water is visible, ser- Two or more tires are flat or
vice fuel/water separator (see paragraph 3-6). missing.
4 FUEL TANK LEVEL
Check fuel level on fuel level gage. Fuel tank is empty.
2-9