TM 5-4310-452-14
4-36. ALTERNATOR REPLACEMENT (Con't).
VOLTAGE REGULATOR TEST (OPEN)
1. Check for 27.5-29 volts at voltage regulator terminal
(3) and positive output terminal (5).
2. Install test jumper JU1 (6) between voltage regulator
terminal (3) and field diode (4).
3. Depress SAFETY CIRCUIT BYPASS button (1) on
control panel (2) and check voltage at voltage
regulator terminal (3).
4. If 1.5-4 volts are present, voltage regulator is "open"
and defective. Replace voltage regulator (see
paragraph 4-38).
5. If no voltage is present, an open field circuit exists,
indicating a defective alternator. Replace alternator.
TA505462
4-73